<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-20 13-23-13
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
91.10 MHz 3/5, 50 dBuV STUDI
Pilot RDS Phase Difference
6.9 kHz 3.2 kHz 82 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
15 kHz 69 kHz 2833 0,3177
Modulation Power
Limit Measuring Tolerance
10,0 dBr 3,0 dBr
MIN AVE MAX % above 13,0 dBr
5,0 dBr 5,75 dBr 6,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" STUDI " F563 0 (No PTY) 1 0 1 1 --:--
RT
"GEORGES BRASSENS - GRAND-PERE "
AF EON
91.1, 91.7 MHz -
FM Scope Station: 91.10 MHz, signal: 3/5 (50 dBuV) Max at: 69 kHz MIN: 15 kHz % above 75 kHz: 0,3177 Acquired: 2024/08/20 13:22:09 Total samples: 2833 Equivalent time: 0:02:21 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200